Trusted Industry Leaders

Serving since 1952

Expert Tool Repair Services

& Tool Rental Options

Enjoy Free Shipping

On All Clearance Items

HIOKI Battery Tester BT3554-52 Pro Kit

Item Number: HUBT3554-52 PRO KIT Categories: , , , , Tag:

$3,754.67

Available on backorder

Hioki battery testers support the maintenance of UPS and storage batteries critical to the life support of all businesses. The BT3554-50 battery internal resistance tester sets the standard for assessing the deterioration and remaining life of UPS and other lead-acid batteries by giving a complete diagnosis via battery resistance testing. The specially designed L2020 Pin Type Lead further improves testing efficiency with an L-shaped tip that lets you reach deep into the battery racks to completely probe the terminals.

Contact us if you have any questions.

Available on backorder

Reviews

Be the first to review “HIOKI Battery Tester BT3554-52 Pro Kit”

We really want your feedback on the products we sell at Tallman Equipment. If you’ve used any of the products we sell (whether you bought them from us or not), leave a review on our website. After writing just 3 reviews, you can receive a free Tallman t-shirt. 

Product Specifications
Weight 2.12 lbs
Shipping Dimensions 2.39 × 7.83 × 5.2 in
Resistance Measurement Range

3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges
Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt)
Testing source frequency: 1 kHz ±30 Hz
With function for avoiding noise frequency enabled: 1 kHz ±80 Hz
Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range)
Open terminal Voltage: 5 V peak

Voltage Measurement Range

± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt

Temperature Measurement Accuracy

Measurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F)
* When using the Clip Type Lead with Temperature Sensor 9460.
* When using the Temperature Probe 9451, add ±0.5°C (±0.9°F) (cable length: 1.5 m [59.1"]).
* When using the Temperature Probe 9451S, add ±0.5°C (±0.9°F) (cable length: 0.1 m [3.94"]).
BT3554-50 standalone accuracy with simulated input: ±0.5°C (±0.9°F)

Absolute Max Input Voltage

60 V DC max (No AC input)

Measurement Time

100 ms

Response Time

Approx. 1.6 sec.

Comparator

Compares measured values with set threshold values to make judgments and reports them to the user.
Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound
When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL
When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL
If the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight.
User-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment )
Savable settings: 200 tables

Memory Functionality

Operation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units)
Saved data: Saved measurement data is linked to profile information.
1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument.
-1. Date and time
-2. Resistance value, voltage value, and temperature
-3. Comparator threshold value and judgment result

2. Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One).
-1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number)
-2. Location: User-defined comment such as location of UPS
-3. Device information: User-defined comment such as UPS management number
-4. Battery number: 1 to 500 (start number, end number)

Measurement Navigator

Operation: Announces the next battery number to be measured via a screen display and audio guidance.
Audio output is generated by a connected mobile device when using the Z3210 and a supported application (GENNECT Cross).
Preparations: Profile information that's been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument.

Communication Interface

USB
Bluetooth® wireless communications (when Z3210 installed)

Other Functions

Temperature measurement (-10.0 to 60.0 °C), Zero-adjustment, Hold, Auto-hold, Auto-memory, Auto-power-save, Clock

Power Supply

LR6 (AA) Alkaline dry battery ×8
Continuous operating time: About 8.3 hr. (without Z3210 installed), About 8.2 hr. (with Z3210 installed and wireless communications active)

Accessories

Carrying Case C1014 ×1, Protector Z5041 ×1, Fuse Set Z5050 ×1, 0 Adj Board ×1, Neck strap ×1, USB cable ×1, Application software CD (GENNECT One) ×1, AA alkaline battery (LR6) ×8, User Manual ×1

Brand

Hioki

More Product Information

HIOKI Battery Tester BT3554-52 Pro Kit

Key Features

  •  Battery measurement can be performed while the battery is connected to its host device, without taking it offline
  • Measure and save data in as fast as 2 seconds, a 60% improvement from the legacy 3554
  • Instantaneously diagnose battery degradation (PASS, WARNING, FAIL) by measuring internal resistance and voltage*1
  • Noise reduction technology improves noise resistance
  • Screen and audio*2 guidance simplifies measurement
  • Measurement data is linked to site information and saved, reducing management man-hours
  • A variety of measurement data can be centrally managed using Hioki’s GENNECT Cross app*3
  • New protector delivers better ergonomic hold and durability in the field.

*1: The thresholds for determining the pass/fail condition of a battery depends on the specifications and standards of the battery manufacturer, battery type, capacity, etc. It is important and necessary to always conduct battery testing against the internal resistance and terminal voltage of a new or reference battery. In some cases, it may be difficult to determine the deterioration state of traditional open type (liquid) lead-acid or alkaline batteries which demonstrate smaller changes in internal resistance than sealed lead-acid batteries.
*2: Audio generated by Bluetooth®-connected device.
*3: Data can be downloaded to tablets and smartphones using Hioki’s dedicated apps available from the Google Play or App Store. (When using the Z3210)

User Guide for Lithium Ion download

User Guide for Lead-Acid download

 

Questions? Contact Us.

As always, if you have any qustions about this tool, or stock quantities contact us by phone at: 877-860-5666 

or by email: sales@tallmanequipment.com

Or fill out this form:

Join The 1952 Society

Want to keep up with everything going on at Tallman, special offers and more? Sign up below